DETERMINATION OF ACTIVATED SLUDGE MODEL ASDM PARAMETERS FOR WASTE WATER TREATMENT PLANT OPERATING IN THE SEQUENTIAL–FLOW TECHNOLOGY
More details
Hide details
1
Zakład Ochrony Wód, Główny Instytut Górnictwa, Pl. Gwarków 1, 40-166 Katowice
Publication date: 2015-01-18
Inż. Ekolog. 2015; 41:79-89
KEYWORDS
ABSTRACT
This paper presents a method for calibration of activated sludge model with the use of computer program BioWin. Computer scheme has been developed on the basis of waste water treatment plant operating in the sequential – flow technology. For calibration of the activated sludge model data of influent and treated effluent from the existing object were used. As a result of conducted analysis was a change in biokinetic model and kinetic parameters parameters of wastewater treatment facilities.
The presented method of study of the selected parameters impact on the activated sludge biokinetic model (including autotrophs maximum growth rate, the share of organic slurry in suspension general operational, efficiency secondary settling tanks) can be used for conducting simulation studies of other treatment plants.